In-Situ Inc.
221 E Lincoln Ave.
Ft. Collins, CO 80524
970-498-1500
Total Dissolved Gas (TDG)
Total Dissolved Gas - TDG Sensor

Supersaturated water
can kill your fish
Dissolved oxygen measurements are not enough--
oxygen levels may be acceptable while nitrogen levels may be lethal.

Get the entire picture -- the sum total pressure of all dissolved gases

Calculate NITROGEN levels from TDG and a dissolved oxygen measurement

Specifications
Brochure
Accessories
Presentation
Frequently Asked Questions

Monitor for supersaturated waters with one unit!
Total dissolved gas pressure is an important parameter for monitoring water quality effectively. When the total pressure of all the gases in the water exceeds the ambient atmospheric pressure at the water surface, supersaturation exists. The effect of excessive supersaturation on fish has been well documented, and if supersaturation exceeds the established safe levels, massive fish kills can occur.

Supersaturation can be caused by numerous man made and natural sources:

  • Dam spillways which allow the discharge to plunge deeply into the receiving water
  • Heated discharge from thermo-electric power plants can raise the temperature of the receiving water to a point of supersaturation
  • Faulty water pumps used in aquaculture recirculatory systems can cause air entrainment if a leak occurs on the suction side of the pump
  • Naturally high levels of nitrogen can be found in well water
  • Algae blooms can cause increased levels of gas in the water

Precautions can be taken to keep supersaturation within safe levels, but accurate in-situ gas measurements must be made to determine if remedial action is effective. TDG Sensors make this measurement quick and easy.

Applications:

  • Use to monitor fish hatcheries, rearing ponds, holding tanks, aquariums, dams, etc.
  • Check well water and other critical water sources for age or for supersaturation caused by heated water or faulty pumps.
  • Check for supersaturation caused by heated water discharge at power plants, industrial sites, and sewer outfalls.

Specifications:

Model
T506 T507 T900
300E
Measurement type Absolute Absolute Differential Pseudo differential against electrical signal. The sensor is an absolute type. Barometric is cancelled electrically.
Equipment Probe Probe Probe/cable Meter/probe/cable
Measurement Method Membrane Diffusion Membrane Diffusion Membrane Diffusion Membrane Diffusion
Measurement Performance
Pressure Range/Output Units 2 atm 400 to 1400 mmHg +/- 400 mmHg +/- 750 mmHg
Pressure Resolution 0.0001 Atm 0.5 mmHg 0.5 mmHg 1 mmHg
Pressure Accuracy +/- 0.002 Atm +/- 1.5 mmHg +/- 1.5 mmHg +/- 1 mmHg
Equilibration Time to 90% of final 5 min 5 min 5 min 5 min
Output Temp Range -30 to +50 ° C -30 to +50 ° C n/a n/a
Output Temp Resolution 0.1 ° C +/- 0.25 ° C n/a n/a
Output Temp Accuracy +/- 0.25 ° C +/- 0.25 ° C n/a n/a
Output
Voltage n/a 0.5 to 5.0 Volt 0 to 5.0 Volt n/a
Digital ASCII : 9600,8,N,1 ASCII : 9600,8,N,1 ASCII : 9600,8,N,1 3 Digit LCD
Signal Output digital digital/analog digital/analog digital (LCD display only)
Physical
Water matrix Natural waters, either fresh, brackish, or saline Natural waters, either fresh, brackish, or saline Natural waters, either fresh, brackish, or saline Natural waters, either fresh, brackish, or saline
Material Delrin, silicone, stainless steel Delrin, silicone, stainless steel Delrin, silicone, stainless steel Delrin, PVC, silicone, stainless steel
Probe Dimensions 300mm x 45mm 300mm x 45mm 300mm x 45mm 127mm x 29mm
Weight n/a n/a n/a 0.9 kg
Membrane Cartridge P/N 70-020 P/N 70-020 P/N 70-020 P/N 70-020
Deployment time before cleaning 2-4 weeks 2-4 weeks 2-4 weeks Not for long term deployment. Spot checker
Electrical
Supply Voltage 6.0 to 13.0 Volts DC External 8.6 to 13.6 Volts DC External 8.0 to 16.0 Volts DC External 2 Internal 9V alkaline batteries
Power consumption (continuous). Duty cycle dependent on controller. 7 mA 7 mA 7 mA 1.5 mA
Environmental
Storage Temp w/ membrane 0 to +60 °C 0 to +60 °C 0 to +60 °C 0 to +60 °C
Storage Temp w/o membrane -40 to +60 °C -40 to +60 °C -40 to +60 °C -40 to +60 °C
Operating Temp 0 to +45 °C 0 to +45 °C 0 to +45 °C 0 to +45 °C
Operational Depth < 53 meters < 53 meters < 53 meters < 53 meters
Max Depth 60 meters 60 meters 60 meters 60 meters
Accessories
Battery/PC connector available available n/a n/a
Cable Available but not included in list price. Waterproof oceanographic plug or bare wire Available but not included in list price. Waterproof oceanographic plug or bare wire 4, 10 or 20 meters fixed included. Vented. Bare wire end for connection to controller 5 meters fixed included. Vented. Bare wire end for connection to controller
Pressure Cap INCLUDED INCLUDED OPTIONAL OPTIONAL
Membrane Cartridge One Included One Included One Included One Included
Application Aquifer testing, aging of water, remediation air sparging, cavitations Hydroelectric, fish protection, cavitations Aquaculture, fisheries, commercial aquariums Aquaculture, fisheries, commercial aquariums

Download Spec Sheet